{"id":12014,"date":"2022-10-19T17:13:12","date_gmt":"2022-10-19T11:13:12","guid":{"rendered":"http:\/\/happymarsbd.com\/?post_type=product&p=12014"},"modified":"2022-10-19T17:13:12","modified_gmt":"2022-10-19T11:13:12","slug":"apollo-3p20k-20000va-long-online-ups-bd-price-in-bangladesh","status":"publish","type":"product","link":"https:\/\/happymarsbd.com\/product\/apollo-3p20k-20000va-long-online-ups-bd-price-in-bangladesh\/","title":{"rendered":"Apollo 3P20K 20000VA Long Online UPS"},"content":{"rendered":"
Description:<\/strong> Main Features Where We Can Use: Technical Talk: Technical Specification:<\/strong><\/p>\n 240V 15% (optional +10%), Min voltage: -45% (optional -20%, -30%), Frequency protection rage: \u00b110%<\/td>\n<\/tr>\n 2.Battery Mode: (50\/60\u00b10.2%)Hz<\/td>\n<\/tr>\n \u22645% with non linear load<\/td>\n<\/tr>\n (charge current can be set according to battery capacity installed)<\/td>\n H:133<\/td>\n<\/tr>\n IEC61000-4-5; IEC61000-4-6; IEC 61000-4-8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Quick Details
\nApollo<\/a> Online UPS provide no gap for even a nanosecond. It has true online dual conversion design and has generator compatible. Apollo 20000va Phase give all types of Protections such as: over\/low-voltage, overcurrent, overload. Intelligent battery management, extended battery life, intelligent self diagnose function and all kinds of fault protection benefit made this ups the best. Modularized design of subsystems bypass back feed protection, battery leakage protection, parallel redundancy design, increase the system reliability. Customizable wide input voltage range and Large size input LCD display on the front pane.The Apollo 3P20K 20000VA Long Online UPS<\/a> Comes with 01 year Warranty.<\/p>\n
\n#Brand_Apollo
\n#Model_3P20K
\n#Type_Online UPS
\n#Capacity_12Volt, 20000VA
\n#Backup or Run Time_2 Hours
\n#Battery Voltage and Ampere_20000VA
\n#Warranty_ 1 year
\n#Without_Internal_Battery_No
\n#Apollo Online UPS<\/p>\n
\n#School and College and University etc
\n#Hospital System
\n#Bank System
\n#Industrial Park
\n#Community System
\n#Commercial Complex
\n#Chain Store
\n#Garments and Industries.
\n#Shop and Any Backup System Use
\n#Small and Big Office etc<\/p>\n
\n#CPU Controlled
\n#Auto re-starts when AC recovers
\n#Silence Setup
\n#Automatic charging (offline charging)
\n#Battery low voltage protection
\n#Overload & Short circuit protection
\n#Wide Input Voltage Range
\n#Automatic Voltage regulation
\n#Apollo Online IPS Auto System.
\n#Delivery Anytime for an Emergency Order.
\n#Home delivery Within Bangladesh.
\n#Call us for any Requirements and Quarries: +8801717668993, 01911076103<\/p>\n\n\n
\n Model<\/td>\n 3P20K<\/td>\n<\/tr>\n \n Capacity (VA\/Watts)<\/td>\n 20K\/16K<\/td>\n<\/tr>\n \n INPUT<\/td>\n <\/td>\n<\/tr>\n \n Nominal voltage<\/td>\n 380\/400\/415Vac, (3Ph+N+PE)<\/td>\n<\/tr>\n \n Operating voltage range<\/td>\n 208~478Vac<\/td>\n<\/tr>\n \n Operating frequency range<\/td>\n 40\u00a0~\u00a070Hz<\/td>\n<\/tr>\n \n Power factor<\/td>\n \u22650.99<\/td>\n<\/tr>\n \n Harmonic distortion (THD)<\/td>\n 2%(100% nonlinear load)<\/td>\n<\/tr>\n \n Bypass voltage range<\/td>\n Max. Voltage: 220V +25% (optional +10%, +15%, +20%) 230V 20% (optional +10%, +15%)<\/p>\n \n Generator input<\/td>\n Support<\/td>\n<\/tr>\n \n OUTPUT<\/td>\n <\/td>\n<\/tr>\n \n Output voltage<\/td>\n 380\/400\/415Vac, (3Ph+N+PE)<\/td>\n<\/tr>\n \n Voltage regulation<\/td>\n \u00b11%<\/td>\n<\/tr>\n \n Power factor<\/td>\n 0.8\/0.9 (Customized)<\/td>\n<\/tr>\n \n Output frequency<\/td>\n 1.Line Mode: \u00b11%\/\u00b12%\/\u00b14%\/\u00b15%\/\u00b110% of the rated frequency (optional)<\/p>\n \n Crest factor<\/td>\n 3:1<\/td>\n<\/tr>\n \n Harmonic distortion (THDv)<\/td>\n \u22642% with linear load<\/p>\n \n Efficiency<\/td>\n 94.5%<\/td>\n<\/tr>\n \n BATTERY<\/td>\n <\/td>\n<\/tr>\n \n Battery voltage<\/td>\n Standard unit: \u00b1216Vdc; Long run unit Optional voltage: \u00b1192V\\\u00b1204V\\\u00b1216V\\\u00b1228V\\\u00b1240Vdc<\/td>\n<\/tr>\n \n Battery type<\/td>\n 12V\/38Ah (standard unit)<\/td>\n<\/tr>\n \n Charge Current (A)<\/p>\n 12A (Max.)<\/td>\n<\/tr>\n \n SYSTEM FEATURES<\/td>\n <\/td>\n<\/tr>\n \n Transfer time<\/td>\n Utility to Batter : 0ms; Utility to bypass: 0ms<\/td>\n<\/tr>\n \n Overload<\/td>\n Line Mode<\/td>\n Load \u2264110%: last 60min, \u2264125%: last 1min, \u2265150% turn to bypass mode immediately<\/td>\n<\/tr>\n \n Bat. Mode<\/td>\n Load \u2264110%: last 10min, \u2264125%: last 1min, \u2264150%: last 5S, \u2265150% shut down UPS immediately<\/td>\n<\/tr>\n \n Short circuit<\/td>\n Hold Whole System<\/td>\n<\/tr>\n \n Overheat<\/td>\n Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately<\/td>\n<\/tr>\n \n Low battery voltage<\/td>\n Alarm and Switch off<\/td>\n<\/tr>\n \n Self-diagnostics<\/td>\n Upon Power On and Software Control<\/td>\n<\/tr>\n \n EPO (optional)<\/td>\n Shut down UPS immediately<\/td>\n<\/tr>\n \n Battery<\/td>\n Advanced Battery Management<\/td>\n<\/tr>\n \n Nose Suppression<\/td>\n Complies with EN62040-2<\/td>\n<\/tr>\n \n Audible & Visual<\/td>\n Line Failure, Battery Low, Overload System Fault<\/td>\n<\/tr>\n \n Status LED & LCD display<\/td>\n Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault<\/td>\n<\/tr>\n \n Reading on the LCD display<\/td>\n Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature<\/td>\n<\/tr>\n \n Communication interface<\/td>\n RS232, RS485, Parallel, Intelligent slot, Relay card (optional), SNMP card (optional)<\/td>\n<\/tr>\n \n ENCIRONMENTAL<\/td>\n <\/td>\n<\/tr>\n \n Operating temperature<\/td>\n 0~40\u00b0C<\/td>\n<\/tr>\n \n Storage temperature<\/td>\n -25\u00a0~\u00a055\u00b0C<\/td>\n<\/tr>\n \n Humidity range<\/td>\n 0\u00a0~\u00a095%\u00a0 (non \u2500 condensing)<\/td>\n<\/tr>\n \n Altitude<\/td>\n <1500m<\/td>\n<\/tr>\n \n Noise level<\/td>\n <55dB<\/td>\n<\/tr>\n \n PHYSICAL<\/td>\n <\/td>\n<\/tr>\n \n Dimension W x D x H (mm)<\/td>\n 780 x 600 x 1200<\/td>\n<\/tr>\n \n Net weight (KG)<\/td>\n S:602<\/p>\n \n STANDARDS<\/td>\n <\/td>\n<\/tr>\n \n Safety<\/td>\n IEC\/EN62040-1; IEC\/EN60950-1<\/td>\n<\/tr>\n \n EMC<\/td>\n IEC\/EN602040-2; IEC61000-4-2: IEC61000-4-3; IEC61000-4-4;<\/p>\n
\nID No: HM2223-1660
\nPrice: 360000 BDT
\nBrand: Apollo
\nModel: 3P20K
\nProduct Title: 20000VA Standard Backup System Long Online UPS, etc<\/p>\n","protected":false},"featured_media":12015,"template":"","meta":{"jetpack_post_was_ever_published":false,"jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":[]},"product_cat":[6342,6345],"product_tag":[6390,6383,1830,6387,6391,6392],"jetpack_publicize_connections":[],"yoast_head":"\n